Middleby Cooking Systems Group PS520E User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
13
SECTION 3
OPERATION
IV. NORMAL OPERATION - STEP-BY-STEP
A. Daily Start-up Procedure
1. Check that the circuit breaker/fused disconnect is in the on
position.
2. Turn the “BLOWER”
switch to the “ON”
or “I” position.
3. Turn the “CONVEYOR”
switch to the “ON” or
“I” position.
4. If necessary, adjust the
conveyor speed setting
by pressing the
or
pushbuttons on the con-
veyor speed controller to
change the displayed
bake time.
5. Adjust the temperature
controller to a desired set
temperature, if neces-
sary.
Press the Set Point
and Unlock keys at
the same time. Wait
for the “SET PT” light
to turn on.
Press the Up Arrow
and Down Arrow
Keys as necessary
to adjust the set-
point.
6. Turn the “HEAT”
switch to the “ON” or “I”
position, and wait for the
“HEAT ON” light to turn
on.
7. Wait for the oven to heat to the setpoint temperature.
Higher setpoint temperatures will require a longer wait.
The oven cavity can reach a temperature of 500
0
F (232
0
C)
in approximately 15 minutes.
8. (Optional) Press the
Temperature key to
show the Actual Tem-
perature in the display,
and wait for the “AC-
TUAL TEMP” light to turn
on. This allows you to
monitor the oven tem-
perature as it rises to the
setpoint.
9. Allow the oven to preheat for 10 minutes after it has
reached the set point temperature.
B. DAILY SHUTDOWN PROCEDURE
1. Turn the “HEAT”
and “BLOWER”
switches to the “OFF” or
“O” position. Note the
blowers will remain in
operation until the oven
has cooled to below
200
0
F (93
0
C).
2. Make certain that there
are no products left on the
conveyor inside the oven.
Turn the “CONVEYOR”
switch to the “OFF”
or “O” position.
3. After the oven has cooled and the blowers have turned
off, switch the circuit breakers/fused disconnect to the
“OFF” or “O” position.
CAUTION
In case of power failure, turn all switches to the “OFF” or
“O” position and remove the product. After the power has
been restored, perform the normal start-up procedure. IF
THE OVEN WAS SWITCHED OFF FOR LESS THAN (5)
FIVE MINUTES, WAIT FOR AT LEAST (5) FIVE
MINUTES BEFORE RESTARTING THE OVEN.
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 39 40

Comments to this Manuals

No comments