4 . Replace the air fingers by pushing in at the back
side. Remember to replace them according to the
numbers marked on them when they were removed.
They must go back in the same way they came out.
IMPORTANT: When inserting fingers the tab
on the outer plate must be in the groove as
shown in Figure 4-18. There is a blocking tab
on the outside of the groove which will prevent
inserting the finger in the groove if the outer
plate is moved away from the flange of the
finger.
SECTION 4
MAINTENANCE
Figure 4-16
Figure 4-17
Extended Lip
Tab on
Outer Plate
Tab on
Outer Plate
Flange of
Finger Manifold